The floating head heat exchanger mainly consists of components such as the shell, floating head tube box, and tube bundle. One end of the tube plate is fixed between the shell and the tube box, and the other end of the tube plate can move freely within the shell, which means that the shell and tube bundle can expand freely, so there is no temperature difference stress between the tube bundle and the shell. Generally, the floating head is designed as a detachable structure, allowing the tube bundle to be freely withdrawn and installed. The floating head of a floating head heat exchanger also has different structural types. It uses clamp rings and bolts to seal and fit the floating head and the tube plate, so that the fluid inside and between the tubes does not leak from each other. This structure is not used much now. According to the design specifications, the floating head cover flange is directly fastened to the hook ring with bolts to seal and fit the floating head flange and the movable tube plate. Although the effective heat transfer area of the tube bundle is reduced, the sealing performance is reliable and the overall structure is relatively compact.
![New Stainless Steel Floating Head Heat Exchanger for Chemical Industry](//www.micstatic.com/athena/img/transparent.png)
SCOPE OF WORK
Mechanical and Fabrication guarantee
Design including strength calculation (including erection condition) stress analysis and detail design based on applicable Codes, Local Regulation, Project Specifications and Standards
Thermal Design (Thermal Rating)
All technical certifications required for design work as per local regulations
Stability check (during transport, lifting and hydrostatic test) and loading data for base design
Structural analysis for main body and its support for operation load
Material procurement
Material Test and Certificates as per applicable Code and Specifications
Manufacturing
Post weld heat treatment as per code and specification
PMI (Positive Material Identification)
All NDEs as per Project Specification
Welding procedure qualification test
WPS & PQR
Welder performance test
Hydrostatic test at BlDDER shop as per Code & Local Regulations, Specifications.
Installation work for vessel internals supplied by Bidder
External surface preparation and painting as per Specification
Packing and marking as per project specifications
Preservation during transportation and storage (Including Seaworthy packing for oversea manufacturer)
Internal protection from moisture: N2 Charge
All activities to meet requirements of Data Sheets, Specifications, Codes and Standards, Local Regulations
![New Stainless Steel Floating Head Heat Exchanger for Chemical Industry](//www.micstatic.com/athena/img/transparent.png)
![New Stainless Steel Floating Head Heat Exchanger for Chemical Industry](//www.micstatic.com/athena/img/transparent.png)
1. Q:Are you a manufacturer or trading company?
A:We are a manufacturer with over thirty years of experience in China.
2.Q:Can we visit your factory before placing orders?
A: Sure, warmly welcome to our factory!
3.Q:What's the information needed if I send one inquiry ?
A : Please tell us the working conditions, mediums,temperature ,pressure, equipment ' s material,size,quantity, and other special requests.
4.Q:How does your factory do quality control?
A: Quality is priority ,we make relevant strict testing before delivery.
Our factory has already obtained ASME, GOST, ISO9001 quality and ISO 14001 Environmental management system certificate.